Skip to main content

Acquire & Record

The basis of all process data analysis is the time synchronous acquisition of relevant data at characteristic places within an automated plant. Like a flight recorder, the iba system records and stores various measurement data available for the long term. The data is recorded continuously (24/7) or triggered by certain defined events. Signals chosen by the user can be visualized on the live monitor.


过程连接优势

Blank

灵活的记录

 时间触发或事件触发

Blank

同时进行多路记录

针对不同用户组

Blank

在线可视化

所有记录数据的

可以结合不同的信号源

归因于同步测量,可以在复杂的分布式系统中检测和理解因果关系。

iba系统采集技术设备中的所有相关数据。无论是直接来自传感器的快速模拟量(高达100kHz),或通过现场总线交换的数据还是来自自动化系统的变量,它们都是独立采集的。一切都可以相互关联。

Blank
流程連接
捕獲並記錄
分析和優化
輸出連接

数据采集的先进典范

Blank

ibaPDA

作为 iba 系统的核心部分,ibaPDA 证明了自身是多年以来用于维护和生产的最为通用的数据采集系统之一。客户端-服务器架构、灵活记录、凭借自动检测轻松配置众多令人信服的功能之一。

了解更多


跟专家交谈

请填写下表,我们会尽快联系

iba_talk_to_expert_zh

Talk to an expert

成功案例

Diesel PowerStation KPIs

Power Station performance monitoring with ibaHD-Server and ibaQPanel

Drive Optimization in a Railcar Dumper and Train Positioner for Mines

iba Oceania designed a measuring system for a multiple AC motor VVVF controlled car positioner in a mine.

Troubleshooting at a minesite

After a scheduled maintenance shutdown in an ore processing plant, the start-up of a particular sequence came
to a grinding halt whenever a certain...

订单信息

请联系当地经销商

Order no.NameDescription
30.770.064 ibaPDA-V7-64 Basic package with server/client application, for 64 measuring signals
30.770.128 ibaPDA-V7-128 Basic package with server/client application, for 128 measuring signals
30.770.256 ibaPDA-V7-256 Basic package with server/client application, for 256 measuring signals
30.770.512 ibaPDA-V7-512 Basic package with server/client application, for 512 measuring signals
30.771.024 ibaPDA-V7-1024 Basic package with server/client application, for 1024 measuring signals
30.772.048 ibaPDA-V7-2048 Basic package with server/client application, for 2048 measuring signals
30.774.096 ibaPDA-V7-4096 Basic package with server/client application, for 4096 measuring signals
30.778.192 ibaPDA-V7-8192 Basic package with server/client application, for 8192 measuring signals
30.779.999 ibaPDA-V7-unlimited Basic package with server/client application, for unlimited measuring signals
30.770.022 ibaPDA-V7-Data-Store Add-on license for writing two more measurement files (*.dat)
30.770.023 ibaPDA-V7-Ultra-Data-Store Add-on license for additional data-storage, 255 measurement files (*.dat) with 20 signals each. Number of files will be reduced, with more signals.
30.770.024 ibaPDA-V7-Client Extension with one more client
30.770.025 ibaPDA-V7-Multi Client Extension with five more clients
30.001.930 ibaPDA Multistation License extension Multi-station application
30.670.050 ibaPDA-SNMP-Server+ Advanced SNMP Server function
30.670.051 ibaPDA-OPC-UA-Server+ Advanced OPC UA Server function
30.670.052 ibaPDA-IEC61850-Server Add-on license IEC61850-Server
Order no.NameDescription
31.000.001 ibaPDA-Interface-S7-Xplorer Xplorer interface for Simatic S7-200/300/400/1200/1500/WinAC/Logo!
31.000.002 ibaPDA-Interface-Codesys-Xplorer Xplorer interface for Codesys-based systems (V2 and V3)
31.000.003 ibaPDA-Interface-AB-Xplorer Xplorer interface for Allen-Bradley PLC5 and SLC500
31.000.004 ibaPDA-Interface-Sigmatek-Xplorer Xplorer interface for Sigmatek systems
31.000.005 ibaPDA-Interface-TwinCAT-Xplorer Xplorer interface for Beckhoff systems
31.000.006 ibaPDA-Interface-B&R-Xplorer Xplorer interface for B&R systems
31.000.007 ibaPDA-Interface-Logix-Xplorer Xplorer interface for Allen-Bradley Logix systems
31.100.008 ibaPDA-Interface-MELSEC-Xplorer Xplorer interface for Mitsubishi MELSEC systems
31.000.030 ibaPDA-Interface-SINAMICS-Xplorer Xplorer interface for SINAMICS drives
31.000.031 ibaPDA-Interface-SIMOTION-Xplorer Xplorer interface for SIMOTION systems
31.001.044 ibaPDA-Interface-Drive-Xplorer Xplorer interfaces for drives (SIMOTION, SINAMICS)
31.001.005 ibaPDA-Interface-EtherNet/IP EtherNet/IP communication interface
31.001.010 ibaPDA-Interface-HPCI-DGM200P HPCI-DGM200P communication interface
31.001.011 ibaPDA-Interface-LANDSCAN LANDSCAN communication interface (infrared line scanner)
31.001.012 ibaPDA-Interface-LMI-Gocator LMI Gocator communication interface (laser profile sensor)
31.001.013 ibaPDA-Interface-Raytek Raytek communication interface (infrared line scanner)
31.001.026 ibaPDA-Interface-AN-X-DCSNet AN-X Automax communication interface
31.001.030 ibaPDA-Interface-RAW-Ethernet Raw-Ethernet communication interface
31.001.040 ibaPDA-Interface-S7-TCP/UDP S7-TCP/UDP communication interface
31.001.045 ibaPDA-Interface-SCRAM-Net SCRAM-Net communication interface
31.001.046 ibaPDA-Interface-Toshiba-ADMAP JAMI1 Toshiba ADMAP communication interface
31.001.047 ibaPDA-Interface-TC-net Communication interface for Toshiba TC-net network
31.001.055 ibaPDA-Interface-Sisteam-TCPIP Sisteam TCP/IP communication interface
31.001.056 ibaPDA-Interface-TDC-TCP/UDP Simatic TDC TCP/UDP communication interface
31.001.065 ibaPDA-Interface-VIP-TCP/UDP ABB VIP-Protokoll TCP/UDP communication interface
31.001.070 ibaPDA-Interface-EGD Ethernet Global Data Memory communication interface
31.001.075 ibaPDA-Interface-Generic-UDP Generic-UDP/IP protocol communication interface
31.001.076 ibaPDA-Interface-Generic-TCP Generic-TCP/IP protocol communication interface
31.001.080 ibaPDA-Interface-GCOM GCOM für ABB Stressometer communication interface
31.001.090 ibaPDA-Interface-IEC61850-Client IEC61850-Client communication interface
31.001.111 ibaPDA-Interface-OPC-UA-Client OPC-UA-Client communication interface
31.001.112 ibaPDA-Interface-MQTT MQTT communication interface
31.001.220 ibaPDA-Interface-Reflective-Memory Reflective Memory Access communication interface
31.001.350 ibaPDA-Interface-Profinet-CP Profinet CP interface to CP1616 and CP1626
Order no.NameDescription
31.001.300 ibaPDA-Request-HPCI HPCI system, HPCI symbolic request channels
31.001.302 ibaPDA-Request-HiPAC Symbolic request channels for Danieli HiPAC PLC
31.001.303 ibaPDA-Request-TwinCAT TwinCAT symbolic request via UDP or ibaBM-eCAT
31.001.310 ibaPDA-Request-S7-DP/PN Simatic S7 system, S7 symbolic request via ibaBM-DP/PN
31.001.311 ibaPDA-Request-S7-UDP Simatic S7 system, S7 symbolic request via UDP, ibaPDA-Interface-S7-TCP/UDP required
31.001.320 ibaPDA-Request-SD Simadyn-D system, Simadyn-D symbolic request channels
31.001.330 ibaPDA-Request-TDC TDC system, Simatic TDC request via FO connection
31.001.340 ibaPDA-Request-X-Pact X-Pact system, X-Pact interface to PROBAS system
31.001.360 ibaPDA-Request-FM458/TDC FM458/TDC system, FM458/TDC request via Profibus
31.001.380 ibaPDA-Request-DTBox-128 Dualis DTBox, 128 signals
31.001.381 ibaPDA-Request-DTBox-1024 Dualis DTBox, 1024 signals
31.001.382 ibaPDA-Request-DTBox-unlimited Dualis DTBox, unlimited number of signals
Order no.NameDescription
30.670.141 ibaPDA-Data-Store-SAP-HANA-64 Writing into a SAP HANA DB; 64 signals 
30.670.142 ibaPDA-Data-Store-SAP-HANA-256       Writing into a SAP HANA DB; 256 signals
30.670.143 ibaPDA-Data-Store-SAP-HANA-1024 Writing into a SAP HANA DB; 1024 signals
30.670.160 ibaPDA-Data-Store-Kafka-16 Writing into an Apache Kafka Cluster, 16 signals
30.670.161 ibaPDA-Data-Store-Kafka-64 Writing into an Apache Kafka Cluster, 64 signals
30.670.162 ibaPDA-Data-Store-Kafka-256 Writing into an Apache Kafka Cluster, 256 signals
30.670.163 ibaPDA-Data-Store-Kafka-1024 Writing into an Apache Kafka Cluster, 1024 signals
30.670.180 ibaPDA-Data-Store-MindSphere-16 Writing into the MindSphere cloud, 16 signals
30.670.181 ibaPDA-Data-Store-MindSphere-64 Writing into the MindSphere cloud, 64 signals
30.670.182 ibaPDA-Data-Store-MindSphere-256 Writing into the MindSphere cloud, 256 signals
30.670.183 ibaPDA-Data-Store-MindSphere-1024 Writing into the MindSphere cloud, 1024 signals