Skip to main navigation Skip to main content Skip to page footer

ibaCMC - CMC2025-09

Informations sur le produit

ibaCMC version v3.6.0

Fond vert avec design d’interface numérique circulaire.

What’s new in this version?

 

Important Note

  • The license ibaCMS-One-Sensor has been extended by OPC-UA-Client licenses supporting two connections in order to allow easy communication with OPC-UA Server (e.g ibaPDA) to get process data for condition monitoring. This has the benefit that the Generic TCP license is no longer required to access data from an existing ibaPDA system.

New Features

  • Trend monitoring and alarming have been updated. The hysteresis option was removed.
  • A new version of the asset report is available. An update is strongly recommended.
  • It is now possible to use in ibaCMC any existing ibaPDA signal from CM-devices like ibaDAQ or ibaM-DAQ, that is acquired through any of the available ibaPDA interfaces.
  • The enhanced envelope BP filter configuration provides more flexibility for sensor filter setup. The downsampling option and cutoff frequency for envelope spectrum calculation can now be configured directly in ibaCMC.
  • Monitoring now operates on averaged trend values instead of raw values. In trend analysis, different aggregation intervals and methods can be applied to the trend data without changing the underlying calculations.
  • The new Cyclic Update mode allows sending statistical values such as RMS, Peak-to-Peak, or Crest Factor at the same interval as the send telegram via TCP send telegrams (requires ibaPDA version 8.13.0 (not yet released) or higher). 

Improvements

  • Improved tooltip in the kinematic grid.
  • Enable typeahead filtering for multi-select dropdowns.
  • Improve default values when creating a new report.
  • Add default options for time span in dashboard settings.
  • Add option to hide cursor labels in signal analysis when clicked.
  • Save font size setting from user settings so it is persisted in the database.
  • Add periodic sidebands for S1 marker in signal analysis.
  • Add option to change date range of dashboard and trend analysis by zooming in while pressing the 'Ctrl' key.
  • Add option to switch between lower and upper thresholds in trend analysis relative view.
  • Show both upper and lower thresholds in trend analysis absolute view.

For a full list of changes, please refer to the version history.