ibaCMC - CMC2026-03

Produkt-Informationen

ibaCMC version v3.7.0

Grüner Hintergrund mit kreisförmigem digitalem Interface-Design.

For using ibaCMC v3.7.x you need an ibaCMC license with a valid EUP date of 2026‑03‑18 or later.

What’s new in this version?


Notes

  • A new version of the asset report template is available. Updating the report is strongly recommended. 

New Features 

  • Signal analysis enhancements:
    • Frequency bands can now be displayed and edited in spectrum views
    • Components of the opened sensor are highlighted in the kinematic grid
    • Threshold lines can now be displayed in the trend analysis chart and zoom controls were added
  • The status history for trends was added in the alarm list
  • A migration wizard for switching from ibaCMU-S or similar devices to ibaDAQ is now available
  • Support for 24 V AC signal type for IEPE sensors was added
  • Preservation of buffer index history for sensors and TCP/IP channels to maintain access to historical measurement data
  • Sensor component history to maintain access to historical measurement data when sensor assignment changes
  • New sensor parameter “Suppress DC Enabled” was added to enable subtraction of the DC component from RMS, vRMS, Crest Factor and RMS * Peak trends.

Important Improvements 

  • Logbook improvements and redesign:
    • List and table view are available now. The Details View was completely redesigned.
    • Logbook now supports additional properties such as status, start time, end time, and tags which can be used for filtering.
    • Every change of the logbook properties is tracked in a history.
    • Images can now be opened in an image viewer with one click only.
    • The logbook is also available in the signal analysis and is available in a new tab.
  • Improved cleanup logic for ibaCMU-S DAT files considering measurement conditions
  • Enhanced notification emails including raw and aggregated values
  • Improved validation and usability in trend analysis and configuration

Bugfixes 

  • Fixed a bug where user profile threw an error if the user did not have certain permissions.
  • Fixed a bug where user password changes did not properly invalidate all active sessions.
  • Fixed wrong data type check in the conf.analysis.xml file which lead to validation errors in exports when using decimal frequency values.
  • Fixed a bug where no data point was marked if no data point was found in the tolerance range in signal analysis.
  • Fixed a bug where sensor signal type dropdown included invalid options.

Documentation

https://docs.iba-ag.com/

New and Updated Manuals 

  • Updated ibaCMC v3.7.0 documentation
     

For a full list of changes, please refer to the version history.

Registered users can download this new version in our download area.