Skip to main navigation Skip to main content Skip to page footer

Privilege Escalation Vulnerability in the iba Install Agent

Security Advisories IBA-2026-03

绿色背景带有圆形数字界面设计。
Publishing Date 2026-02-16
Last Update 2026-04-21
Tracking IDIBA-2026-03
CVSS Base Score7.2
CVSS Vector CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:A/VC:H/VI:H/VA:L/SC:H/SI:H/SA:H

Summary

If you install the following application as a regular user without administrative privileges, you will be prompted to provide admin rights during the installation. After the installation, you can select a checkbox to start the application immediately. At this point, the permissions are not properly reverted, which means the application runs with elevated privileges, resulting in a privilege escalation.
This can be exploited after the installation and automatic start of the application via the installer option. For example, you can open a command‑line interface that runs in the same user context as the iba application in this case with administrator privileges, because these privileges were not correctly reverted after the installation.

Example (ibaVision):
After the installation, I can use the “Open ibaVision configuration” option to navigate to C:\Windows\System32\cmd.exe and start the command prompt with the same privileges that ibaVision currently has — in this case administrator privileges, because they were not correctly reverted after the installation.

After signing out and signing back in to the Windows user account, the elevated privileges are lost and the application runs with normal user permissions again.

Affected products

This applies to all iba products up to the versions listed below:

  • ibaCMC v3.5.1
  • ibaCapture v5.5.2
  • ibaVision v3.1.1
  • ibaAnalyzer v8.3.4
  • ibaDatCoordinator v4.0.3
  • ibaHD-Server v3.5.2

How do I know that I’m affected?

If you have installed any of the products listed above, you are affected.

Mitigation

Restart your system after installing the iba software.

Solution

With the following versions, the issue has been fixed in the installer:

  • ibaCMC v3.6.0
  • ibaCapture v5.5.3
  • ibaVision v3.1.2
  • ibaAnalyzer v8.3.5
  • ibaDatCoordinator v4.0.4
  • ibaHD-Server v3.6.0

Customer Actions

Please install the update as described in the solution

Timeline

2025-11-07Noted by the Security Team
2025-11-18Fix for the Problem in Version ibaCMC v3.6.0
2025-11-20Fix for the Problem in Version ibaCapture v5.5.3
2025-12-10Fix for the Problem in Version ibaVision v3.1.1
2026-02-16Fix for the problem in ibaAnalyzer v8.3.5
2026-02-18Fix for the Problem in Version ibaDatCoordinator v4.0.4
2026-03-31Fix for the Problem in Version ibaHD-Server v3.6.0