Skip to main content

ibaHD-Server

随时可调用的历史数据

使用高采样率历史数据 (Historical Data, HD) 服务器不仅可以快速查找过去的事件也同样适用于连续和长期运行的过程。借助缩放功能,只需单击鼠标即可浏览,从每年、每月或每周概览直至毫秒的数据范围。

ibaHD-Server概览



  • 长时间持续记录数据
  • 无需 ibaPDA 即可直接访问历史数据
  • 用于显示历史数据的直观界面,包含例如浏览、滚动、跳转至某个特定日期等功能
  • 快速缩放功能用于显示从每年、每月或每周概览到毫秒范围的数据
  • 记录和显示由事件触发的消息

Product Highlights

模块化产品理念支持高度灵活的配置选项并提供根据不同需要完美定制的解决方案。

Navigation and Zoom Function in the ibaHD Trend View

With the ibaPDA client, measured signals can be selected from time ranges such as seconds, hours, weeks, months or even years and displayed. The selected signals are displayed as a trend in the ibaPDA client in no time. With the navigation and zoom function, the displayed time range can be enlarged or reduced to the highest resolution at a mouse click.

One Single Server for more than one Data Store

One ibaHD-Server can be used for administrating more than one HD data store. Both the time-based and length-based recording of signals as well as the recording of event messages are treated like normal data recording in ibaPDA.

Rapid Access to Events from the Past

Messages for product changes or noticeable process states can be formulated as events and stored in the ibaHD-Server. The messages are controlled by trigger signals and stored as events in an event-based HD store with the current time stamp.

Product Features

Continuous Data Recording over Long Periods of Time

ibaHD-Server is basically used as data storage for measured data from ibaPDA server. For this purpose, ibaPDA server sends measured data directly to the ibaHD-Server via TCP/IP connection.

Navigation and Zoom Function in the ibaHD Trend View

With the ibaPDA client, measured signals can be selected from time ranges such as seconds, hours, weeks, months or even years and displayed. The selected signals are displayed as a trend in the ibaPDA client in no time.

Rapid Access to Events from the Past

Messages for product changes or noticeable process states can be formulated as events and stored in the ibaHD-Server. The messages are controlled by trigger signals and stored as events in an event-based HD store with the current time stamp.

Attach Additional Information Directly at the Origin Time

Predefined or free texts can be added as annotations directly in the trend graph. This additional information can be supplemented by images, PDF documents or other files.

User Management

In order to protect the data in the ibaHD-Server against unauthorized access, the user management offers the possibility to assign authorizations to individual users.

Video Images Extend Analysis Options

The combination of historical data and video images offers completely new possibilities for analyzing processes or disturbances. Video images provide additional visual information wherever processes are difficult to measure or cannot be reliably detected by sensors.

One Single Server for more than one Data Store

One ibaHD-Server can be used for administrating more than one HD data store. Both the time-based and length-based recording of signals as well as the recording of event messages are treated like normal data recording in ibaPDA.

Saving Data Using Backups

A backup function offers flexible options for individual backup strategies for HD data stores, like e.g. automated data backups according to a defined schedule or manual backups with customized parameters.

License-free Offline Analysis

Backups of HD data can be opened as read-only HD data store for analysis purposes without a license on the analysis computer. The data can comfortably be evaluated and used for reports with ibaAnalyzer.

Simply Import Data Files

Measurement files recorded with ibaPDA in DAT format can also be integrated into the concept of long-term recording.

Analysis in ibaAnalyzer

Data from ibaHD-Server can be conveniently retrieved and displayed with the ibaAnalyzer analysis program.

Modular Product Design for Customized Needs

The basic licenses for ibaHD-Server are graded according to the number of signals and comprise one ibaHD-Server, two HD data stores and two HD clients.

This software is one of many useful add-ons of ibaPDA

作为 iba 系统的核心部分,ibaPDA 证明了自身是多年以来用于维护和生产的最为通用的数据采集系统之一。客户端-服务器架构、灵活记录、凭借自动检测轻松配置众多令人信服的功能之一。

了解更多

ibaPDA 的扩展

可以通过带有附加功能的大量实用插件模块化扩展 ibaPDA 系统

ibaQPanel

显示质量数据 - 实时、分颜色

ibaQDR

采用任何分辨率、基于长度的质量数据

ibaInSpectra

實時監控過程振動

跟专家交谈

请填写下表,我们会尽快联系

隐私保护

通过选择一个国家,我的请求将被转发给iba AG负责销售和支持的国家分支机构。

资源简介

英语, .pdf, 8.4 MB
英语, .pdf, 744.8 KB

请联系 当地经销商

Order no.NameDescription
30.800064ibaHD-Server-V2-T-64Basic license historical data recording, 64 tags (signals),
incl. 2 HD clients and 2 HD data stores
30.800256ibaHD-Server-V2-T-256Basic license historical data recording, 256 tags, incl. 2 HD clients and 2 HD data stores
30.801024ibaHD-Server-V2-T-1024Basic license historical data recording, 1024 tags (signals),
incl. 2 HD clients and 2 HD data stores
30.802048ibaHD-Server-V2-T-2048Basic license historical data recording, 2048 tags (signals),
incl. 2 HD clients and 2 HD data stores
30.806666ibaHD-Server-V2-T-unlimitedBasic license historical data recording, unlimited tags (signals),
incl. 2 HD clients and 2 HD data stores
30.700010ibaHD-Server Single ClientLicense extension HD-Server: single client
30.700015ibaHD-Server Multi ClientLicense extension HD-Server: 5 additional HD access points
30.700002Upgrade-HD-T-64 to HD-T-256License extension HD-Server: 64 tags to 256 tags
30.700003Upgrade-HD-T-256 to HD-T-1024License extension HD-Server: 256 tags to 1024 tags
30.700004Upgrade-HD-T-1024 to HD-T-2048License extension HD-Server: 1024 tags to 2048 tags
30.700005Upgrade-HD-T-2048 to HD-T-unlimitedLicense extension HD-Server: more than 2048 tags
30.700020ibaHD-Server Data StoreLicense extension HD-Server: 2 more data stores

EUP concept for ibaHD-Server: Beginning with ibaHD-Server V2.0, the licenses contain free product updates for a period of 2 years from the purchase date on. By purchasing the product "Extended update period (EUP)", ibaHD-Server users are entitled to install products updates for another year in order to benefit from continuous improvements and new features. An EUP is always valid from the date the previous license expires.