Skip to main navigation Skip to main content Skip to page footer

Hardware - HWA2021-01

Product Information

ibaBM-PN firmware version v01.06.001

Green background with a circular digital interface design.

What’s new in this version?

Basic PROFINET and general network diagnostic features allow to monitor quality relevant network parameters like load, used bandwidth, counters for good, bad, RT and IRT frames, device connection status, connections attempts and measured cycle times.

Online Hexviewer to show captured binary data.

Improved startup time of the sniffer firmware in order to capture network traffic earlier after power on.

New output subslot size of 240 bytes, to support Simatic CP allowing just devices up to this size.

Support "uneven" IRT update cycles like e.g. 1.250ms.

ibaPDA v7.3.0 or higher is required as well as the GSDML file ‘GSDML-V2.35-ibaBM-PN-20210301‘ or newer.

Registered users can download this new firmware from our website.