Skip to main navigation Skip to main content Skip to page footer

Expanding the iba System With I/O Modules of the 750 Series From WAGO/Beckhoff

WAGO-I/O-System 750

The iba system can be expanded easily and costeffectively with 750 series I/O modules from WAGO and K-bus modules from Beckhoff. The two central units ibaW-750 and ibaNet750-BM-D offer different possibilities of connection to the iba system: via Ethernet or fiber optics.

Talk to an Expert
ibaW-750Green background with a circular digital interface design.

Decentralized I/O System for Various Applications

The flexible, decentralized WAGO I/O system is an ideal supplement to the iba system. All common I/O module types are supported.

There are two ways of simply integrating the I/O modules into the iba system with automatic detection (plug & play): on the one hand via an Ethernet connection with the central unit ibaW-750, on the other hand via fiber optics (FO) with ibaNet750-BM-D. The two variants differ mainly with regard to the possible sampling rates, the necessary cabling and the operating distance.

Central Units at a Glance

Easy Configuration, Automatic Detection

Both central units can be easily configured in ibaPDA as usual. The devices including the connected I/O modules are automatically detected in ibaPDA. 

When using ibaW-750, the device and the ibaPDA computer must be in the same LAN.

Coupling to K-Bus

A maximum data volume of 2048 bytes can be transferred via the K-bus.The sampling rate depends on the cycle time on the K-bus.

Module Types

The following I/O module types are supported:

  • analog and digital I/O modules
  • incremental encoders
  • SSI inputs
  • RTDs
  • thermocouples
  • measuring bridges
  • modules for power measurement

Measure Power, Calculate Characteristics

ibaW-750 also supports various modules for power measurement of the 750-494 and 750-495 series. The modules measure current and associated voltages in the three-phase supply network and calculate characteristic values, e.g.

  • effective/reactive/ apparent power
  • effective/reactive/ apparent energy
  • power factor
  • phase angle
  • frequency

The power measurement modules are particularly suitable for acquiring power characteristics in the low-voltage range directly at consumers. In addition, simple, but not standard-compliant grid analyses can be carried out on consumers. 

Comfortable Configuration in ibaPDA

The power measurement modules are comfortably configured in ibaPDA. In addition, a large number of diagnostic signals are available, which can trigger an alarm in ibaPDA if, for example, a preset limit value is exceeded or not reached.

 ibaW-750ibaNet750-BM-D
PC/Hardware
  • Ethernet connection
  • Any PC, even as a virtual machine
  • Standard Ethernet cable
  • Operating distance plant-wide, worldwide (VPN tunnel)
  • PC with PCIe slot and iba-FO input/output card required
    or
  • ibaDAQ
  • FO cable
  • up to 2000 m distance
Transmission
  • Ethernet
  • Packet-oriented
  • Error correction with packet repetition
  • Fiber optic cable (FO)
  • Synchronous to the acquisition
  • No error correction necessary, due to dedicated FO cable
Acquisition
  • Deterministic
  • Synchronized with ibaPDA
  • up to 250 I/O modules
  • Deterministic
  • Synchronous via FO
  • up to 255 I/O modules
Configuration
  • I/O modules are detected automatically (plug & play)
  • I/O modules are detected automatically (plug & play)

WAGO-I/O-System 750 Functions

Explore Real Applications

Get inspired by product use cases and learn how value is created.

Companies That Rely on iba

These leading companies already use this component of the iba system.

ALUNORF Logo
AMAG Logo
AVL Logo
BRS Logo
Daimler Logo
KraussMaffei Logo
Krones Logo
Leoni Logo
MTU Logo
Novelis Logo
novem Logo
posco Logo
Primetals Logo
RWE Logo
Saarstahl Logo
Salzgitter Logo
Siemens Energy Logo
Siemens Logo
SIG Logo
SMS group Logo
storaenso Logo
TATA Steel Logo
Tenaris Logo
Tennet Logo
Thermo Fisher Logo
thyssenkrupp Logo
vallourec Logo
voestalpine Logo
Voith Logo
VW Logo

Join the 2,500+ Customers Worldwide

Contact us – we look forward to hearing from you! Our experts are happy to answer any questions and help you with any challenges you may face.

Talk to an Expert

Success Stories

Read the inspiring success stories of our satisfied customers.

Service & Downloads

Download important resources or contact our support team for further assistance.

Order no.NameDescription
15.140010ibaNet750-BM-DBus module for WAGO-I/O-System 750
15.140020ibaW-750Central unit for WAGO-I/O-System 750
15.144000ibaNet750-400/2-DI 3ms2 Channel Digital Input Terminal; DC 24 V; 3.0 ms; Positive Switching
15.144010ibaNet750-401/2-DI 0,2ms2 Channel Digital Input Terminal; DC 24 V; 0.2 ms; Positive Switching
15.144020ibaNet750-402/4-DI 3ms4 Channel Digital Input Terminal; DC 24 V; 3.0 ms; Positive Switching
15.144021ibaNet750-402/4-DI 3ms, Ext.4 Channel Digital Input Terminal; DC 24 V; 3.0 ms; Positive Switching, extended temperature range 
15.144030ibaNet750-403/4-DI 0.2ms4 Channel Digital Input Terminal; DC 24 V; 0.2 ms; Positive Switching
15.144041ibaNet750-404/1Ch-UP COUNTER, max. 100kHzUp Counter DC 24 V; Release Input
15.144043ibaNet750-404/1Ch-Frequency Counter max. 100kHzFrequency Counter DC 24 V
15.144050ibaNet750-405/2-DI 230V AC2 Channel Digital Input Terminal; AC 230 V; 10 ms; Positive Switching
15.144060ibaNet750-406/2-DI 120V AC2 Channel Digital Input Terminal; AC 120 V; 10 ms; Positive Switching
15.144080ibaNet750-408/4-DI DC 24 V; 3,0 ms4 Channel Digital Input Terminal; DC 24 V; 3.0 ms; Negative Switching
15.144100ibaNet750-410/2-DI DC 24V2 Channel Digital Input Terminal; DC 24 V; 3.0 ms; Proximity Switch
15.144120ibaNet750-412/2-DI 48V/3ms2 Channel Digital Input Terminal; DC 48 V; 3 ms; Proximity Switch
15.144150ibaNet750-415/4-DI AC/DC 24V4 Channel Digital Input Terminal; AC/DC 24 V; 20 ms; Negative Switching
15.144300ibaNet750-430/8-DI DC 24V8 Channel Digital Input Terminal; DC 24 V; 3.0 ms; Positive Switching
15.144310ibaNet750-431/8-DI DC 24V8 Channel Digital Input Terminal; DC 24 V; 0.2 ms; Positive Switching
15.144520ibaNet750-452/2-AI 0..20mA2 Channel Analog Input Terminal; 0-20 mA; Differential Input
15.144530ibaNet750-453/4-AI 0..20mA4 Channel Analog Input Terminal; 0-20 mA; Single Ended
15.144540ibaNet750-454/2-AI 4-20mA2 Channel Analog Input Terminal; 4-20 mA; Differential Input
15.144550ibaNet750-455/4-AI 4-20mA4 Channel Analog Input Terminal; 4-20 mA; Single Ended
15.144560ibaNet750-456/2-AI +/-10V Differential Input2 Channel Analog Input Terminal; ± 10V; Differential Input
15.144570ibaNet750-457/4-AI +/-10V4 Channel Analog Input Terminal; ± 10V; Single Ended
15.144600ibaNet750-460/4-AI PT1004 Channel Analog Input Terminal; PT100 (RTD)
15.144603ibaNet750-460/4-AI PT10004 Channel Analog Input Terminal; PT1000 (RTD)
15.144610ibaNet750-461/2-AI PT1002 Channel Analog Input Terminal; PT100 (RTD)
15.144613ibaNet750-461/2-AI PT10002 Channel Analog Input Terminal; PT1000 (RTD)
15.144620ibaNet750-462/2-AI Thermo2 Channel Analog Input Terminal; Thermocouple
15.144650ibaNet750-465/2-AI 0..20mA, single ended2 Channel Analog Input Terminal; 0-20 mA; Single Ended
15.144660ibaNet750-466/2-AI 4..20mA, single ended2 Channel Analog Input Terminal; 4-20 mA; Single Ended
15.144670ibaNet750-467/2-AI 0..10V2 Channel Analog Input Terminal; 0-10 V; Single Ended
15.144690ibaNet750-469/2-AI Thermo Diag,Type K2 Channel Analog Input Terminal; Thermocouple, Type K
15.144691ibaNet750-469/2-AI Thermo Diag,Type S2 Channel Analog Input Terminal; Thermocouple, Type S
15.144692ibaNet750-469/2-AI Thermo Diag,Type L2 Channel Analog Input Terminal; Thermocouple, Type L
15.144696ibaNet750-469/2-AI Thermo Diag,Type J2 Channel Analog Input Terminal; Thermocouple, Type J
15.144750ibaNet750-475/2-AI AC/DC 0-12 Channel Analog Input Terminal; 0-1 A AC/DC; Differential Input
15.144790ibaNet750-479/2-AI +/-10V Diff.2 Channel Analog Input Terminal; ± 10V; Differential Input
15.144910ibaNet750-491/1-AI Resistance Meas. Bridge1 Channel Analog Input Terminal for Resistance Jumpers (DMS)
15.144911ibaNet750-491/1-AI Resistance Meas. Bridge 65ms1 Channel Analog Input Terminal for Resistance Jumpers (DMS); 125ms
15.144930ibaNet750-493/3-Ph-1ibaNet750-493/3-Ph-1
15.144931ibaNet750-493/3-Ph-5ibaNet750-493/3-Ph-5
15.144940ibaNet750-494/3-Ph-1A3-Phase Power Measurement Module (480V/1A) 
15.144941ibaNet750-494/3-Ph-5A3-Phase Power Measurement Module (480V/5A) 
15.144950ibaNet750-495/3-Ph-1A3-Phase Power Measurement Module (690V/1A) 
15.144951ibaNet750-495/3-Ph-5A3-Phase Power Measurement Module (690V/5A) 
15.145010ibaNet750-501/2-DO 0,52 Channel Digital Output Terminal; DC 24 V; 0.5 A; Positive Switching
15.145020ibaNet750-502/2-DO 22 Channel Digital Output Terminal; DC 24 V; 2.0 A; Positive Switching
15.145040ibaNet750-504/4-DO 0,5A4 Channel Digital Output Terminal; DC 24 V; 0.5 A; Positive Switching
15.145070ibaNet750-507/2-DO 24V 2,0A Diagn.2 Channel Digital Output Terminal; DC 24 V; 2.0 A; Positive Switching; Diagnostics
15.145120ibaNet750-512/2-DO Relais (Closing Contact)2 Channel Digital Output Terminal; Relay; AC 230 V, DC 30 V, AC/DC 2 A; non-floating; 2 make contacts
15.145130ibaNet750-513/2-DO Relais (Closing Contact)2 Channel Digital Output Terminal; Relay; AC 230 V, DC 30 V, AC/DC 2 A; Isolated outputs; 2 make contacts
15.145140ibaNet750-514/2-DO Relais (Alternating Contact)2 Channel Digital Output Terminal; Relay; AC 125 V, AC 0.5 A, DC 30 V , DC 1 A; Isolated outputs; 2 changeover contacts
15.145170ibaNet750-517/2-DO Relais (Alternating Contact)2 Channel Digital Output Terminal; Relay; AC 230 V , 1 A; Isolated outputs; 2 changeover contacts
15.145300ibaNet750-530/8-DO 0,5A8 Channel Digital Output Terminal; DC 24 V; 0.5 A; Positive Switching
15.145500ibaNet750-550/2-AO 0..10V2 Channel Analog Output Terminal; 0-10 V
15.145520ibaNet750-552/2-AO 0..20mA2 Channel Analog Output Terminal; 0-20 mA
15.145540ibaNet750-554/2-AO 4..20mA2 Channel Analog Output Terminal; 4-20 mA
15.145550ibaNet750-555/4-AO 4..20mA4 Channel Analog Output Terminal; 4-20mA
15.145560ibaNet750-556/2-AO +/-10V2 Channel Analog Output Terminal; ± 10V
15.145570ibaNet750-557/4-AO +/-10V4 Channel Analog Output Terminal; 0-10 V
15.146000ibaNet750-600/End-TerminalEnd Module
15.146020ibaNet750-602/Supply Terminal without Diag.Supply Module; Field; DC 24 V
15.146100ibaNet750-610/Supply Terminal w. Diag.Supply Module; Field; DC 24 V; Fuse Holder; Diagnostics
15.146120ibaNet750-612/Supply TerminalSupply Module; Field; AC/DC 230 V
15.146140ibaNet750-614/Power Distr. ModSupply/Distribution Module; Field; AC/DC 230 V
15.146270ibaNet750-627/Terminal Bus Extension End ModuleEnd Module; Bus Extension; Outgoing
15.146280ibaNet750-628/Terminal Bus Extension Start ModuleCoupler Module; Bus Extension; Incoming/Outgoing
15.146300ibaNet750-630/1Ch-SSI InputSSI-Interface
15.146310ibaNet750-631/1Ch-Incr. EncoderIncremental Encoder; RS422 (differential)
15.146370ibaNet750-637/1Ch-Incr. Encoder 32BitIncremental Encoder

What would you like to do today?

By choosing a country, my request will be forwarded to the country branch of iba AG responsible for sales and support.Privacy Policy